1. Кіріспе
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Prity FGW15 wood-burning stove with oven and back boiler. This appliance is designed to provide both room heating and hot water for central heating systems, while also offering a functional oven for cooking. Please read this manual thoroughly before using the appliance and retain it for future reference.
The Prity FGW15 stove complies with European standards EN 13240:2001 and EN 13299:2001, ensuring its quality and safety for domestic use.
2. Қауіпсіздік туралы ақпарат
Кәсіби орнату қажет: This appliance requires professional installation by a qualified technician to ensure safe and correct operation, as well as compliance with local building codes and regulations. Improper installation can lead to fire hazards, carbon monoxide poisoning, and other serious risks.
2.1 Жалпы қауіпсіздік ескертулері
- Жұмыс істеп тұрғанда пешті ешқашан қараусыз қалдырмаңыз.
- Балалар мен үй жануарларын пештің ыстық беттерінен алыс ұстаңыз.
- Пештің жанында тез тұтанатын материалдарды сақтамаңыз.
- Ensure adequate ventilation in the room where the stove is installed.
- Regularly inspect the flue pipe and chimney for blockages or damage.
- Only use recommended fuel types.
2.2 Жанғыш материалдарға дейінгі ең аз аралық
Өрт қаупін болдырмау үшін жанғыш материалдардан келесі минималды қашықтықты сақтаңыз:
- Артқы: 400 мм
- Тараптар: 400 мм
- Алдыңғы: 800 mm (within the radiation area of the glass)
These distances are critical for safety. Consult your installer for specific requirements based on your installation.
2.3 Permissible Fuel
Тек пайдаланыңыз құрғақ отын as fuel. The wood moisture content should be 16 ± 4% according to EN 13240:2006, EN 13229:2006, EN 12815:2006 Annex B, Table B.1. Do not burn treated wood, plastics, coal, or any other materials not specified for wood-burning stoves, as this can damage the appliance, create hazardous emissions, and void your warranty.
3. Өнімнің құрамдас бөліктері
The Prity FGW15 is a versatile appliance combining a wood-burning firebox, an oven, and a back boiler for central heating. Key components include:
- Өрт жәшігі: Main combustion chamber for burning wood. Features heat-resistant ceramic glass.
- Пеш: Located above the firebox, equipped with heat-resistant ceramic glass and a temperature gauge.
- Back Boiler: Integrated system for heating water for central heating, with a capacity of 15 liters.
- Manual Dampers: Екі дampers for controlling air supply and flame intensity.
- Шойын тор: Located in the firebox for efficient combustion.
- Түтін құбырын қосу: Top-mounted outlet for chimney connection.
- Су қосылымдары: Inlet and outlet for the central heating system.

3.1-сурет: Алдыңғы view of the Prity FGW15 stove, highlighting the firebox, oven, and ash drawer.

3.2-сурет: Артқы view of the Prity FGW15 stove, illustrating the cold and hot water connections for the back boiler and the flue pipe outlet.
4. Техникалық шарттар
Below are the detailed technical specifications for the Prity FGW15 wood-burning stove:
Figure 4.1: Key dimensions of the Prity FGW15 stove.
| Ерекшелік | Техникалық сипаттама |
|---|---|
| Үлгі | FGW15 |
| Бренд | Мақтаныш |
| Өнім өлшемдері (D x W x H) | 53 x 57 x 93 см |
| Салмағы | 136 кг |
| Материал | Шойын |
| Nominal Room Heating Power | 5 кВт |
| Nominal Water Heating Power | 15 кВт |
| Total Nominal Heat Output | 19.8 кВт |
| Қазандықтың сыйымдылығы | 15 литр |
| Cold Water Inlet / Hot Water Outlet | 2.5 см (1 дюйм) |
| Түтін құбырының диаметрі | 130 мм |
| Тиімділік | 76.5% |
| Approximate Heating Surface Area | 114 m² (for room heating) |
| Firebox Dimensions (W x D x H) | 465 x 240 x 430 мм |
| Oven Dimensions (W x D x H) | 380 x 400 x 200 мм |
| Максималды жұмыс қысымы (су) | 1.25 бар |
| Түтін газының температурасы | 192 °C |
| CO in Flue Gas | 1031.3 mg/Nm³ (0.0985 %) |
| Dust Content | 26.4 мг/Нм³ |
| NOx Content | 102.7 мг/Нм³ |
| CxHy Content | 43.8 мг/Нм³ |
5. Орнату талаптары
Installation of the Prity FGW15 stove must be carried out by a certified professional in accordance with all national and local building and fire safety regulations. This includes proper chimney connection, flue pipe installation, and integration with your central heating system.
5.1 Chimney and Flue Pipe
- Ensure the chimney is clean, structurally sound, and of adequate height and diameter for the stove's output.
- The flue pipe diameter is 130 mm. Use appropriate connectors and seals.
- All flue pipe connections must be airtight to prevent smoke leakage.
5.2 Water Connections for Back Boiler
The back boiler requires connection to a closed or open central heating system. The cold water inlet and hot water outlet connections are 2.5 cm (1 inch). A qualified plumber must perform these connections, ensuring proper pressure relief valves, expansion tanks, and circulation pumps are installed according to system requirements and local codes.
5.3 Positioning and Clearances
Refer to Section 2.2 for minimum clearances to combustible materials. The stove must be placed on a non-combustible hearth extending beyond the appliance as required by local regulations.
6. Пайдалану нұсқаулары
Before operating, ensure all installation checks are complete and the central heating system (if connected) is filled and vented.
6.1 Starting the Fire
- Алдыңғы ауа беру тесіктерінің екеуін де ашыңыз dampер және түтін dampтолығымен.
- Place a small amount of kindling and firelighters on the cast iron grate in the firebox.
- Light the kindling. Once it is burning well, add small pieces of dry firewood.
- От жағатын бөлменің есігін мықтап жабыңыз.
- Allow the fire to establish fully before adding larger logs.
6.2 Air Control and Flame Intensity
Пеш екі қолмен басқарылатын пешпен жабдықталғанampers:
- Алдыңғы Д.ampе: Controls the primary air supply to the combustion chamber. Opening it increases the burn rate and heat output. Closing it reduces the burn rate.
- Түтін Dampе: Regulates the intensity of the flame and the draft through the flue. Adjust this to achieve optimal combustion and prevent excessive heat loss up the chimney.
d екеуін де реттеңізampers to achieve a steady, efficient burn. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or poor draft.
6.3 Пешті пайдалану
The oven utilizes heat from the firebox below. The oven temperature will vary depending on the intensity of the fire. Monitor the oven temperature gauge and adjust the fire's intensity as needed for cooking. Preheat the oven thoroughly before placing food inside.
7. Техникалық қызмет көрсету
Regular maintenance is crucial for the safe and efficient operation of your Prity FGW15 stove.
7.1 Күлді кетіру
Remove ash from the ash drawer regularly, ideally before each use or when the ash bed becomes thick. Allow the stove to cool completely before removing ash. Dispose of ash in a metal container with a tight-fitting lid, away from combustible materials.
7.2 Әйнекті тазалау
Clean the ceramic glass on the firebox and oven doors as needed. Use a specialized stove glass cleaner or a damp cloth dipped in fine ash (when cold) to remove soot. Avoid abrasive cleaners or tools that could scratch the glass.
7.3 Flue Pipe and Chimney Cleaning
The flue pipe and chimney must be inspected and cleaned by a qualified chimney sweep at least once a year, or more frequently if heavy use or creosote buildup is observed. Blockages can lead to dangerous chimney fires and carbon monoxide accumulation.
7.4 Жалпы тексеру
Барлық тығыздағыштарды, топсаларды жәнеampers for wear or damage. Ensure water connections for the back boiler are free from leaks. Replace any worn parts promptly.
8. Ақаулықтарды жою
This section addresses common issues you might encounter with your Prity FGW15 stove.
| Мәселе | Ықтимал себебі | Шешім |
|---|---|---|
| Бөлмеге кіретін түтін | Blocked chimney/flue, insufficient draft, door opened too quickly, wet fuel. | Check chimney/flue for blockages. Ensure dampers are open. Use dry fuel. Open door slowly. |
| Төмен жылу шығару | Insufficient air supply, wet fuel, small fire, poor insulation. | Ашық ауа dampers. Use dry, seasoned wood. Build a larger fire. Check room insulation. |
| Өрт тым тез жанады | Excessive air supply, door not sealed properly. | Жабық ауа dampers partially. Check door seals and replace if necessary. |
| Шыны тез қарайып кетеді | Wet fuel, insufficient air for combustion, low burning temperature. | Use dry fuel. Increase air supply. Ensure fire burns hot enough. |
| Central heating not heating effectively | Low fire intensity, air in system, pump malfunction, system blockage. | Increase fire intensity. Bleed radiators. Check circulation pump. Consult a plumber. |
If you encounter persistent problems that cannot be resolved using this guide, contact a qualified technician or your seller for assistance.
9. Сәйкестік және сертификаттау
The Prity FGW15 wood-burning stove is manufactured and tested to meet stringent European standards.
9.1 European Standards
This appliance complies with:
- EN 13240:2001/A2:2004/AC:2007 (Roomheaters fired by solid fuel)
- EN 13299:2001 (Roomheaters with boiler fired by solid fuel)
9.2 Energy Efficiency Label
The Prity FGW15 has an energy efficiency rating of A. This label provides information on the energy performance of the appliance.
Figure 9.1: Energy Efficiency Label for Prity FGW15.
9.3 Өнімділік туралы декларация
A Declaration of Performance (DoP) is available, confirming the essential characteristics and performance of the product in accordance with Regulation (EU) No 305/2011.
Figure 9.2: English Declaration of Performance for Prity FGW15.
10. Кепілдік және қолдау
For warranty information, please refer to the terms and conditions provided at the point of purchase or contact your seller directly. In case of technical issues, questions, or the need for spare parts, please contact the retailer from whom you purchased the Prity FGW15 stove. Ensure you have your purchase details and the product model number (FGW15) available when contacting support.
Ask a question about this manual