Dino-Lite AM413ZTA

Dino-Lite Pro AM413ZTA Digital Microscope and MS35B Pole Stand User Manual

1. Кіріспе

This manual provides instructions for the Dino-Lite Pro AM413ZTA Digital Microscope and the MS35B Pole Stand. The AM413ZTA is a 1.3-megapixel handheld digital microscope featuring a rotatable polarizer filter, designed for detailed observation and analysis. The MS35B is an economical, rigid vertical stand that provides stable support and adjustable positioning for the Dino-Lite microscope.

2. Негізгі мүмкіндіктер

2.1 Dino-Lite Pro AM413ZTA Digital Microscope

  • Polarizer Filter: A rotatable polarizer filter is integrated to significantly reduce reflection glare from surfaces, enabling clear viewing of transparent or highly reflective materials such as jewelry, skin, glass, plastic, metal, or soldering.
  • H11 Housing: This second-generation housing design incorporates an improved magnification dial for smooth adjustment and focusing, a scroll lock feature to secure desired magnification/focus, and a cable strain relief (SR) for enhanced durability against pulls and twists.
  • Үлкейту: Offers a magnification range of 10x to 50x and up to 220x.
  • Кескін сенсоры: 1.3 Megapixel resolution for clear image capture.

2.2 MS35B Pole Stand

  • Vertical Stability: Provides rigid vertical support for the Dino-Lite microscope.
  • Rotational Perspective: Allows up to 360 degrees of horizontal axis rotation.
  • Adjustable Working Distance: Offers up to 8 inches of vertical working distance from the object.
  • Бүйірлік Viewбұрыштар: The scope holster is mounted on a slider with a ball and socket joint, permitting up to 45 degrees of adjustable lateral viewбұрыштар.
  • Тұрақты құрылыс: Manufactured from resilient stainless steel and lightweight recycled aluminum for smooth adjustment and stability.

3. Орнату

3.1 Stand Assembly (MS35B)

  1. Place the base plate on a stable, flat surface.
  2. Insert the vertical pole into the designated slot on the base plate and secure it firmly.
  3. Attach the microscope holder assembly to the vertical pole at the desired height. Ensure all screws are tightened to prevent movement.

3.2 Microscope Installation (AM413ZTA)

  1. Gently insert the Dino-Lite AM413ZTA microscope into the holster of the MS35B stand. Ensure it is securely seated.
  2. Connect the microscope's USB cable to an available USB port on your computer.
  3. Install the Dino-Lite software (typically included with the product or available for download from the manufacturer's website). Follow the on-screen instructions for software installation.
Dino-Lite Pro AM413ZTA Digital Microscope mounted on the MS35B Pole Stand.

Figure 1: Dino-Lite Pro AM413ZTA Digital Microscope mounted on the MS35B Pole Stand, ready for use.

4. Пайдалану нұсқаулары

4.1 Powering On and Software Launch

The microscope is powered via the USB connection. Once connected to your computer and the software is installed, launch the Dino-Lite application. The live image from the microscope should appear on your screen.

4.2 Үлкейтуді және фокусты реттеу

  1. Үлкейту: Rotate the magnification dial on the microscope body to adjust the desired magnification level. The H11 housing provides a smooth movement for this adjustment.
  2. Айналдыру құлпы: To maintain a specific magnification, engage the scroll lock feature on the H11 housing.
  3. Фокус: Use the focus ring on the microscope to bring the image into sharp clarity. For fine adjustments, you may also adjust the height of the microscope on the MS35B stand.
Dino-Lite Pro AM413ZTA Digital Microscope, handheld view, showing the magnification dial.

Figure 2: Handheld view of the Dino-Lite AM413ZTA, highlighting the magnification dial and clear housing.

4.3 Using the Polarizer Filter

The AM413ZTA features a rotatable polarizer filter to reduce glare. To use it:

  1. Observe the object through the microscope.
  2. Gently rotate the polarizer ring located near the objective lens.
  3. Continue rotating until the reflection glare is minimized or eliminated, allowing for a clearer view of the surface or subsurface features.
Микроскопиялық view of a metal object with significant glare before applying polarization.

Figure 3: Microscopic view of a metal object with glare.

Микроскопиялық view of the same metal object with reduced glare after applying polarization.

Figure 4: Microscopic view of the same object with glare reduced by the polarizer.

4.4 Кескін және бейне түсіру

The Dino-Lite software provides functions for capturing still images and recording videos. Refer to the software's help documentation for detailed instructions on using these features, including measurement tools.

Microscopic image displaying measurement annotations on a mechanical component.

Figure 5: Microscopic image with measurement annotations.

Close-up microscopic view of a circuit board with intricate details and gold-plated contacts.

Figure 6: Microscopic view схемалық платадан.

5. Техникалық қызмет көрсету

  • Линзаны тазалау: Use a soft, lint-free cloth specifically designed for optical lenses to clean the microscope's objective lens. Avoid abrasive materials or harsh chemicals.
  • Денені тазарту: Микроскоптың корпусын сүртіңіз және жұмсақ шүберекпен тұрыңыз, damp cloth. Do not immerse any part of the device in liquid.
  • Сақтау орны: Store the microscope and stand in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the original packaging or a protective case if available.

6. Ақаулықтарды жою

  • Экранда сурет жоқ:
    • Ensure the USB cable is securely connected to both the microscope and the computer.
    • Verify that the Dino-Lite software is running and the correct device is selected.
    • Try connecting to a different USB port or another computer to rule out port or computer issues.
  • Бұлыңғыр кескін:
    • Adjust the focus ring on the microscope.
    • Ensure the object is within the microscope's working distance. Adjust the height of the microscope on the stand if necessary.
    • Clean the objective lens for any smudges or dust.
  • Excessive Glare:
    • Rotate the polarizer filter on the microscope to reduce reflections.
    • Adjust the lighting conditions of your workspace.
  • Бағдарлама құрылғыны анықтамайды:
    • Reinstall the Dino-Lite software and drivers.
    • Компьютеріңізді қайта іске қосыңыз.
    • Өндірушіні тексеріңіз website for updated drivers or software.

7. Техникалық сипаттамалар

ЕрекшелікТехникалық сипаттама
Үлгі нөміріAM413ZTA
Кескін сенсоры1.3 мегапиксель
Үлкейту диапазоны10x~50x, 220x
ПоляризаторYes, Rotatable
Тұрғын үйH11 (Improved magnification dial, scroll lock, cable strain relief)
Жарық көзі түріГалоген
Material (Microscope)Металл
Material (Stand)Stainless steel, recycled aluminum
Item Weight (Microscope)0.35 фунт
Нақты бұрышы View45 градус
Қуат көзіBattery Powered (Note: USB connection provides power for operation)
Объективті линзаның сипаттамасыАхроматикалық

8. Кепілдік туралы ақпарат

The Dino-Lite Pro AM413ZTA Digital Microscope and MS35B Pole Stand are covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Dino-Lite website for detailed information regarding warranty terms, conditions, and registration procedures.

9. Қолдау

For technical assistance, software updates, or further inquiries, please visit the official Dino-Lite website or contact their customer support. You can find more information and resources at the Dino-Lite Store on Amazon.

© 2023 Dino-Lite. All rights reserved.

Ask a question about this manual